24/48 Commissioning
Bosch Rexroth AG, HEDE 10-3X, RE 30277-02-B/07.2016
8.1 Operating and display elements
321
9 10 11
4 5 6 7 8
12
1 to 8: Indicator LEDs
LED 1 Switching status OUT1 (is on when output 1 is connected
through).
LED 8 No function
LED 2 - 7 System pressure in the given unit of measurement.
9:Enterbutton[●]
Selection of the parameters and acknowledgement of the parameter
values.
10to11:Arrowkeysup[▲]anddown[▼]
- Setting of the parameter values (scrolling by holding pressed;
incremental by pressing once).
12: Alphanumeric display, 4 digits
- Display of the current system pressure.
- Indication of the parameters and parameter values.