Commissioning 27/48
RE 30277-02-B/07.2016, HEDE 10-3X, Bosch Rexroth AG
cFL / cFH
Lower / upper value for color change.
Parameter only active after selection of a freely denable
color window in the coLr parameter: [r-cF] or [G-cF].
diS Update rate and orientation of the display.
8.3 Parameter setting
During parameter setting the unit remains in operation. It continues
to monitor with the existing parameters until the parameter setting is
completed.
8.3.1 Parameter setting in general
3 steps have to be taken for each parameter setting:
1 Select parameter
Press [●] to get to the menu.
Press [▲] or [▼] until the
requested parameter is
displayed.
2 Set parameter value
▶ Press [●] to edit the
selected parameter.
Press [▲] or [▼] for min. 1 s.
After 1 s: Set value is changed:
Incrementally by pressing the
button once or continuously by
keeping the button pressed.
Numerical values are incremented continuously with [▲] or
decremented with [▼].