Commissioning 33/48
RE 30277-02-B/07.2016, HEDE 10-3X, Bosch Rexroth AG
8.6.4 Reading the min/max values for the system pressure
▶ Select [Hi] or [Lo] and briey press [●].
[Hi] = maximum value, [Lo] = minimum value.
Clear memory:
▶ Select [Hi] or [Lo].
▶ Press and hold [▲] or [▼] until [----] is displayed.
▶ Briey press [●].
8.6.5 Resetting all parameters to factory setting
▶ Select [rES].
▶ Press [●].
▶ Press and hold [▲] or [▼] until [----] is displayed.
▶ Briey press [●].
We recommend noting down your own settings before
carrying out a reset (→ 14.3 Factory setting).
8.6.6 Set color change of the display color
▶ Select [coLr] and set the function:
– [rEd] = display color red (independent of
measured value).
– [GrEn] = display color green (irrespctive of
measured value).
– [r1ou] = display color red when OUT1 switches.
– [G1ou] = display color green when OUT1 switches.
– [r-cF] = display color red when the measured value
is between the freely denable limit values
[cFL]*
)
and [cFH]*
)
.
– [G-cF] = display color green when the measured
value is between the freely denable limit
values [cFL]*
)
and [cFH]*
)
.
*
)
The parameters [cFL] and [cFH] can only be selected in
the menu tree when [r-cF] or [G-cF] was activated.