9-54 Extended Drive Functions MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Digital Inputs/Outputs on Optional Module MD1
The status of the digital inputs/outputs on the MD1 is displayed in the
following parameters:
P-0-0081, Parallel output 1
contains the information regarding the digital output bits
P-0-0082, Parallel input 1
contains the information regarding the digital input bits
The following applies to these parameters:
bit set ("1")
At the assigned input/output a HIGH level (+24 V) is provided.
bit not set ("0")
At the assigned input/output a LOW level (0 V) is provided.
Note: There is no additional configuration check as the restriction of
the IDN selection lists already prevents invalid configurations.
Hardware Requirements
The assignment and number of digital inputs/outputs depends on the
respective control section and is contained in the respective hardware
description (Project Planning Manual).
See documentation "Project Planning Manual for Control Sections"
Status of Digital Inputs/Outputs