MPH-02, MPB-02, MPD-02 Drive Control 6-79
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
6.6 Power Supply
Possibilities of Power Supply for IndraDrive
Brief Description
For IndraDrive devices we basically distinguish two lines:
modular line, consisting of supply unit and modular inverter
(IndraDrive M)
non-modular line, so-called converter devices, including power supply
and inverter (IndraDrive C)
The power supply of the motors controlled via inverter is realized by a
direct voltage power bus (DC bus). In the case of the modular line, this
bus is supplied by the supply unit connected to the mains. Converters are
supplied by the mains connection via the integrated supply unit.
S-0-0380, DC bus voltage
P-0-0114, Undervoltage threshold
P-0-0118, Power supply, configuration
P-0-0460, Module group, control word
P-0-0461, Module group, status word
P-0-0806, Current mains voltage crest value
P-0-0809, Properties of charging circuit
P-0-0810, Minimum mains crest value
P-0-0815, Nominal mains voltage crest value
P-0-0833, Braking resistor threshold
P-0-0844, Braking resistor load
P-0-0858, Data of external braking resistor
P-0-0859, Data of internal braking resistor
P-0-0860, Control word of power section
P-0-0861, Status word of power section
E2026 Undervoltage in power section
E2040 Device overtemperature 2 prewarning
E2050 Device overtemp. Prewarning
E2061 Device overload prewarning
E2086 Prewarning supply module overload
E2802 HW control of braking resistor
E2810 Drive system not ready for operation
E2814 Undervoltage in mains
E2026 Undervoltage in power section
E2818 Phase failure
E2819 Mains failure
E2820 Braking resistor overload prewarning
E2829 Not ready for power on
E8025 Overvoltage in power section
E8028 Overcurrent in power section
8057 Device overload, current limit active
Pertinent Parameters
Pertinent Diagnostic Messages