EasyManua.ls Logo

Bosch Rexroth IndraDrive MPH-02 - Page 651

Bosch Rexroth IndraDrive MPH-02
728 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MPH-02, MPB-02, MPD-02 Handling, Diagnostic and Service Functions 10-69
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
trigger level
(P-0-0027)
trigger edge negative
(P-0-0030; bit 1 set)
control signal
status signal
end of recording
DK000049v01_en.fh7
t
time resolution
(P-0-0031)
start of recording
(P-0-0028, bit 0)
trigger start
(P-0-0029, bit 1)
number of valid measured
values (P-0-0150)
recording active
(P-0-0029, bit 0)
signal > trigger level
(P-0-0029, bit 8)
signal < trigger level
(P-0-0029, bit 9)
internal trigger
(P-0-0037, bit 0)
trigger function completed
(P-0-0029, bit 3)
no. of measured val. after
trigger event (P-0-0033)
delay function completed
(P-0-0029, bit 4)
trigger control offset
(P-0-0035)
external trigger signal
(P-0-0036)
Fig. 10-30: External trigger with offset measurement (P-0-0028; bit 1 = 1)
Note: The use of the external trigger source with trigger offset
determination is described in the section "Synchronizing the
Measuring Signals of Several Axes" (see below).
Selecting the Trigger Edges
In parameter P-0-0030, Oscilloscope: trigger edge it is possible to set
at which edge of the trigger signal the "internal trigger" is released. The
following options are available:
triggering at the positive edge
triggering at the negative edge
triggering at both edges
triggering when trigger signal equals trigger level
See Parameter Description "P-0-0030, Oscilloscope: trigger edge"
Trigger Edge (P-0-0030)
Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 426-5480 www.cmafh.com

Table of Contents

Related product manuals