MPH-02, MPB-02, MPD-02 Handling, Diagnostic and Service Functions 10-77
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Communication via RS232 Interface
The RS232 interface is particularly intended to be used for connecting a
PC with installed "DriveTop" commissioning tool.
transmission rates from 9600 to 115,200 Baud
max. transmission distance 15 m
ASCII protocol or SIS protocol (8-bit each)
parity bit according to parameter P-0-4095, RS-232/485 Parity
one stop bit
PC with DriveTop
PLC
drive
controller
n
drive
controller
n+1
drive
controller
n+2
drive
controller
n+3
RS232
master communication
(e.g. parallel I/O or field
bus)
DF0020v1.fh7
Fig. 10-36: Communication via RS232 interface (example: DriveTop)
Features