Fig.5-4: IndraWorks Dialog for CCD Settings
The resulting axis addressing in MLD-M is:
● X-axis (axis address 2) → Axis 1 in MLD
● Y-axis (axis address 4) → Axis 2 in MLD
MLD Configuration
In the drive PLC, you have to select permanent control for the CCD master.
Fig.5-5: IndraWorks Dialog for MLD Configuration
Bosch Rexroth AG DOK-INDRV*-MLD-APPLI**-AW02-EN-P
Rexroth IndraDrive Rexroth IndraMotion MLD Application Examples
24/97
Double-Axis Positioning Control (Pick and Place)