2 Safety instructions
2�1 About this chapter
The product has been manufactured inaccordance with generally accepted
engineering standards. There isstill, however, arisk ofpersonal injury orproperty
damage ifthis chapter and the safety instructions inthis documentation are not
observed.
Read this documentation completely and thoroughly before working with
theproduct.
Keep the documentation inalocation where it isaccessible toall users atall
times.
Always include the required documentation when passing the product
ontothirdparties.
2�2 Intended use
Control blocks are hydraulic components, meaning that in their application area
they are classified neither as complete nor as partly completed machinery in the
sense of the EC Machinery Directive2006/42/EC. The component isexclusively
intended toform partly completed machinery orcomplete machinery together with
other components. The component may only becommissioned after it has been
installed inthe machine forwhich it isintended and the required safety ofthe
entire system has been established inaccordance with the machinery directive.
The control blocks have been developed to control various hydraulic consumers on
mobile and standalone working machines.
Deviating use isonly permitted following consultation with BoschRexroth.
The product can be employed as a safety-relevant part of a control system. It
does not however include a safety function as it is unable to provide or realize
such afunction independently. If the product is to be employed to realize safety
functions, additional measures are to be defined by the system manufacturer
or system planner in either the control system or the safety-relevant part of the
control system. Parameters in this respect can be found in standards governing
functional safety such as ISO13849, IEC62061 or specific technical guidelines.
Observe the technical data, the application and operating conditions and
the power limits asspecified inthe datasheetand inthe order confirmation.
Information about approved hydraulic fluids can befound inthe corresponding
datasheet.
Intended use includes having completely read and understood this documentation
and particularly chapter2 "Safety instructions" onpage9.