EasyManuals Logo

Bose PowerShare PS602P Service Manual

Bose PowerShare PS602P
119 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #115 background imageLoading...
Page #115 background image
115
Access advanced digital loudspeaker processing features using the free web-downloadable PowerShare Editor
software. The PowerShare Editor software accesses all of the FreeSpace
®
, Panaray
®
, and RoomMatch
®
Utility
loudspeaker EQs, as well as room EQ, standard mixing, band pass filtering, limiters, delay, mute polarity
inversion, and output polarity inversion.
The fixed architecture enables the following features:
• 9-Band Parametric EQ (PEQ)
Adjust room EQ, per channel. The default setting is Flat.
• Standard Mixer
The 2x2 or 4x4 standard mixer allows for routing of any input(s) to any output(s). The default setting routes
each input to its output (1:1). For example, INPUT 1 is routed to OUTPUT 1, INPUT 2 is routed to OUTPUT
2, etc.
• Band Pass
Set high-pass (HPF) and low-pass filters (LPF), per channel. The default setting is Flat. In Hi-Z output
mode, a 50 Hz HPF is automatically added to the Hi-Z selected outputs. The loudspeaker EQ is applied
after the 50 Hz HPF.
• 9-Band Speaker EQ
Choose any FreeSpace, Panaray, or RoomMatch Utility Bose loudspeaker EQ, with associated limiter
settings, per channel. The default setting is Flat.
• Vpeak and Vrms Limiters
Both values are loaded automatically when a Bose loudspeaker is selected in the Loudspeaker EQ block.
The values are always adjustable. In 70V mode, a 100 Vpeak limiter is automatically loaded. In 100V
mode, a 141 Vpeak limiter is automatically loaded. These are maximum values that can be lowered if
necessary using the PowerShare Editor software.
• Delay
Apply up to 50 ms of delay on Channels 1 & 2 for each amplifier model, in increments of 0.1 ms. The
default setting is 0 ms delay.
• Output
Each output can be set to inverted output polarity. The default state is non-inverted.
• Mute Polarity
The default state is Normally Open (NO), where a short across the mute connector will mute all outputs.
The mute polarity can be inverted to Normally Closed (NC), where an open across the mute connector will
mute all outputs.
Setup files can be saved and loaded into other similar PowerShare amplifiers for quick duplification of amplifier
settings.
Amplifier DIP Switch Settings
The position of the CONFIG DIP switch, located on the rear panel of the amplifier, determines whether the
amplifier settings are configured using the PowerShare Editor software or the rear panel controls.
If the CONFIG DIP switch is set to SOFTWARE, configure the amplifier using PowerShare Editor software.
You can disconnect the amplifier from the PC when setup is complete and the amplifier will retain the
settings.
If you use the PowerShare Editor software to configure the amplifier, and then change the DIP switch
setting to REAR, the amplifier loads the EQ dial settings instead, and the settings configured using the
software return to their default states.
If the CONFIG DIP switch is set to REAR, configure the amplifer using the controls on the rear panel of the
amplifier.
If you configure the amplifier using the rear panel and then change the DIP switch setting to SOFTWARE,
the amplifier settings do not change until the PowerShare Editor software is connected to the amplifier and
new settings are pushed to the amplifier from the software.
PowerShare
TM
Editor Software

Other manuals for Bose PowerShare PS602P