BPW-EA-AS 37772001dePage 14
English
3 Maintenance intervals
Commissioning Before each
journey
Annually
Visual inspection
Inspect all components for damage and untightness X X --
Check whether the shut-o valve on the AirSave Control Box
is opened
XX--
Check connection lines, valve hoses and rotors -- X --
Check electrical and pneumatic lines -- -- X
Function checks
Check outlet pressure on the AirSave Control Box
(see chapter 5) and all tyres
X--X
1)
Check AirSave LED display CMP5 X -- X
Check rotor and BPW AirSave hub cap adapter for untight-
ness
X-- X
1)
6 months after installation, then annually
For heavy-duty applications, check more frequently (e.g. o -road, extreme weather conditions)