ENGLISH 19 / 19 CHAP. 5–GENERAL SPECIFICATION
gs-200
CHAP. 5 - GENERAL SPECIFICATIONS
5.1 GENERAL SPECIFICATIONS
* Measuring ranges :
• CO........................... from 0 to 9.99 % Res. 0.01
• CO2.......................... from 0 to 19.9 % Res. 0.1
• HC hexane.................. from 0 to 10000 PPM Res. 1
• 02............................. from 0 to 100 % Res. 0.01
• No............................ from 0 to 5000 PPM Res 10
• Lambda..................... from 0.5 to 2 Res. 0.001
• Revolutions................. from 300 to 9990 rpm Res. 10
• Oil temp.................. from 20 to 150 °C Res. 1
• Measuring gas intake 4 l/min.
• Automatic continuous condensation discharge
• Semiautomatic leak test
• Automatic flow monitoring
• Automatic O2 sensor exhausted monitoring
• Automatic compensation of environmental pressure from 850 to 1050 mB
• Automatic calibration (with sample gas bottle)
• Automatic autozero
• Time to warm up to 20°C - 10 minutes.
• Response time < 10 sec.
• Revolution counter pulse reception via cable or via wireless radio system
• Oil temperature input for PT100, or via wireless radio system
• RS 232 serial link
• 485 serial link in network
• 12 Volt DC power supply
• Power draw 1.5A DC
• Operating temperature from 5° to 40° C
• Dimensions 220 x140 x 430 mm
• Weight 5 Kg