ENGLISH 51 / 51 CHAP.8 – MAINTENANCE
gs-200
CHAP. 8 - MAINTENANCE
This chapter contains all the instructions you require to keep your instrument in a
perfectly efficient condition.
The BRAINBEE Assistance Department will be happy to supply you with all the
information and means required to achieve this result in a rapid and efficient way.
8.1 9.1 - How to clean the filtering system
The filters installed in the system are very important since they protect the delicate
internal devices from dirt and impurities. This is why it is essential to clean them when
required.
The arrow points to the cup which must be unscrewed to access the filters.
Two types of filter are housed in the cup:
• Coalescent, which must be replaced when its white surface becomes black, or at
least once a month.
• Gauze, which must be washed at least once a month and replaced at least once
every six months.