4. Keep on pouring until the lubricant level has risen above the level line in the inspection
window.Place back the breather cap.
See also
For the required quantity of lubricant, Refer to "Lubricant table pump" on page 83
Refer to "Torque figures" on page 85
8.6 Changing oil in the gearbox
1. Refer to documentation supplied with the motor and gearbox for the procedure on oil change.
8.7 Changing the hose
Removing the hose
1. Isolate the pump from the electrical supply.
2. Close any shut-off valves in the suction and discharge line to minimise the loss of process fluid.
Note: The drain plug is in the cover of the pump.
3. Place a tray (A) under the drain plug. The tray must be large enough to contain the lubricant,
possibly contaminated with product fluid, from the pumphead. Remove the drain plug (E).
Collect the lubricant from the pump housing in the tray.
4. Check that the breather vent mounted on the rear is not obscured.
5. Position the drain plug and tighten it to the specified torque.
46 m-bredel-25-32-en-05