4. Rinse the pumphead with clean water and remove all residues. Make sure that no rinsing
water remains in the pumphead.
5. Check the pressing shoes for wear or damage and replace them if necessary.
See also
Refer to "Maintenance and periodic inspections" on page 41
CAUTION
When the pressing shoes are worn the compression force of the hose
decreases. If the compression force is too low, this results in a loss of
capacity by the backflow of the liquid to be pumped.
Backflow results in a reduction of the life of the hose.
6. Place the seal ring (C) in the groove of the cover (B).
7. Refit the cover (B). Make sure that the four bolts (A) are refitted and that they are tightened in
the correct order, diagonally opposite each other.
8. Connect the pump to the electrical supply.
9. Switch on the electrical supply.
See also
Refer to "Torque figures" on page 85
Fitting the hose
1. Clean the (new) hose on the outside and fully lubricate the outside with Bredel Genuine Hose
Lubricant.
50 m-bredel-25-32-en-05