5.3.3 Creating a P2 program
▪ Press returnkey "2" as many times as necessary to get to
the main screen,
▪ Press setting & activating time program knob "3";
‘Setting & activating timer programme’ opens,
▪ Select ‘P2: week/weekend’ by turning setting knob "1",
▪ Press setting knob "1"; ‘P1: week/weekend’ opens.
You can choose between ‘Week’ and ‘Weekend’. With ‘Week’ you can set a day program for Monday through
Friday. With ‘Weekend’ you can set a day program for Saturday and Sunday.
Week
▪ Select ‘Week’ by turning setting knob "1",
▪ Press setting knob "1"; ‘Week’ opens,
(*) You have a choice from ‘Period 1’, ‘Period 2’, ‘Period 3’, ‘Period 4’, ‘Period 5’ and ‘Period 6’. Every period
is a part of the day in which you can set a ventilation mode.
Perform the following actions to set period 1:
▪ Select ‘Period 1’ by turning setting knob "1",
▪ Press setting knob "1"; ‘Period 1’ opens,
▪ Select ‘start time’ by turning setting knob "1",
▪ Press setting knob "1"; ‘start time’ opens,
▪ Change ‘start time’ by turning setting knob "1"; You have a range of between 3.00 hrs and 2.59 hrs,
▪ Press setting knob "1" to confirm start time.
Now set the ventilation mode for period 1. Perform the following actions for this:
▪ Select ‘Ventilatiestand’ by turning setting knob "1"
▪ Press setting knob "1";‘Ventilatiestand’ opens
▪ Set the ventilation mode for period 1 by turning setting knob "1"
▪ Press setting knob "1" to confirm the airflow for period 1
You have set the ventilation mode for period 1 You can set period 2 through 6 in the same manner. A period ends
when a new one starts.
Weekend
▪ Follow the steps from paragraph 5.3.3, until you have a choice between ‘Week’ and ‘Weekend’
▪ Select ‘Weekend’ by turning setting knob "1"
▪ Press setting knob "1"; ‘Weekend’ opens
▪ Continue the steps from paragraph 5.3.3 at (*)
Brink Air Control- Ventilation 614884-B