© 2022 Brivo Systems LLC. All rights reserved. PUB-Brivo ACS6100 Installation Manual
9
Brivo ACS6100 Installation Manual
• 1 box
• 1 hinge pair short
• 1 hinge pair long
b) 1 lock and key set
c) An identify label to be adhered to the inside of the door
d) Battery and PSU cardboard box
• 1 power supply board (B-ACS6100-PSB)
• 1 pair of battery wires
• 1 AC/DC power adapter
• 1 14Ah lead-acid battery or 2 7Ah lead-acid batteries
6. If additional large expansion chassis have been ordered with the control panel, locate and check the
contents of each Large Expansion Chassis Kit (B-ACS6100L-EXP). Each large expansion chassis can hold up
to eight boards, including any combination of door and/or Input Output boards. Combined, there may be
enough chassis kits to hold 1 MAIN CONTROL BOARD, and any combination of 14 door and/or Input/
Output boards. Each large expansion chassis (B-ACS6100L-EXP) should contain the following parts:
a) 1 metal chassis
• 1 lid
• 1 box
• 1 hinge pair short
• 1 hinge pair long
b) 1 lock and key set
c) An identify label to be adhered to the inside of the door
d) Battery and PSU cardboard box
• 2 power supply board (B-ACS6100-PSB)
• 2 pair of battery wires
• 2 AC/DC power adapters
• 2 14Ah lead-acid batteries
Plan your installation and decide where to install the B-ACS6000-MBE/MBS panel
1. Determine the size of your control panel.
a) In addition to the control chassis, which contains the MAIN CONTROL BOARD, there may be
several additional expansion chassis.
b) The control chassis contains the MAIN CONTROL BOARD, which also serves as a 2-door
board, and may also contain up to two additional expansion boards (DOOR BOARD and
or INPUT OUTPUT BOARD) in any combination (if using a B-ACS6100R-E chassis or six
additional expansion boards (DOOR BOARD and/or INPUT OUTPUT BOARD) in any
combination if using a B-ACS6100L-E chassis).
c) Each standard expansion chassis (B-ACS6100R-EXP) may contain up to four boards, in any
combination of DOOR BOARDs and/or INPUT OUTPUT BOARDs.
• Each DOOR BOARD has two terminal nodes, each of which contains a complete set
of terminals for controlling a door. This means that each DOOR BOARD can be used
to control two doors.
• The same inputs and outputs that drive a door can also be used for other devices. In
other words, DOOR BOARDs do not need to be used to control doors.
WARNING: Door Wiring
If a node is to be used for a door, do not connect any other device to the following terminal blocks: REX & DOOR,
DOOR LOCK RELAY, and READER.
• An INPUT OUTPUT BOARD cannot be used to control a door; however, it can be used in any
circumstance that uses contact closure to track change of status.