FastIron# show chassis
chassis Power supply/fan/temperature
FastIron# show chassis
Power supply 1 (NA - AC - Regular) present, status ok Power supply 2 not present
Fan 1 ok, speed (auto): [[1]]<->2<->3
Fan 2 ok, speed (auto): [[1]]<->2<->3
Fan controlled temperature: 50.5 deg-C
Fan speed switching temperature thresholds:
Speed 1: NM<----->53 deg-C
Speed 2: 37<----->55 deg-C
Speed 3: 50<-----> 90 deg-C (shutdown)
Sensor B Temperature Readings:
Current temperature : 50.5 deg-C
Warning level.......: 55.0 deg-C
Shutdown level......: 90.0 deg-C Sensor A Temperature Readings:
Current temperature : 42.0 deg-C Boot Prom MAC: 001b.ed7e.7040 Management
MAC: 001b.ed7e.7040 FWS648G Router#tempera
temperature temperature sensor commands
FastIron#temperature war
warning Temperature at which the module sends a warning
FastIron#temperature warning 40
FastIron#
!!! Temperature is over warning level !!!
SYSLOG: <9>Jan 1 00:00:00 FWS648G Router System: Temperature 50.0 C degrees,
warning level 40.0 C degrees, shutdown level 90.0 C degrees
SYSLOG: <12>Jan 1 00:00:00 FWS648G Router System: Temperature is over warning
level
FastIron#temper
temperature temperature sensor commands
FastIron# temperature shut 45