Brocade FastIron WS Hardware Installation Guide 43
53-1002188-01
Managing FastIron WS temperature settings
4
DRAFT: BROCADE CONFIDENTIAL
To display the system log, enter the following command at any CLI level.
Changing the temperature warning and shutdown levels
The default warning temperatures and the default shutdown temperatures for the device shown
below.
For all models.
Warning temperature is 85C (measured on mainboard)
Shutdown temperature is 90C (measured on mainboard)
NOTE
These temperatures reflect the temperature of the board inside the device.
To change the temperature at which the device sends a warning, enter a command such as the
following at the Privileged EXEC level of the CLI.
FWS 624 Router#temperature warning 47
Syntax: temperature warning <value>
The <value> can be 0 – 125.
To change the shutdown temperature, enter a command such as the following at Privileged EXEC
level of the CLI.
FWS 624 Router#temperature shutdown 57
Syntax: temperature shutdown <value>
The <value> can be 0 – 125.
Changing the shutdown temperature threshold
The default warning temperature is 45.0C. You can change the warning temperature using the
following command. The valid range is 0 – 125
C.
The FastIron WS devices will automatically reset and reload the software when the internal
temperature reaches or exceeds the configured shutdown level for five minutes. This release also
adds the capability for the system to register negative temperature settings.
FWS 624 Router#show log
Syslog logging: enabled (0 messages dropped, 0 flushes, 0 overruns)
Buffer logging: level ACDMEINW, 8 messages logged
level code: A=alert C=critical D=debugging M=emergency E=error
I=informational N=notification W=warning
Static Log Buffer:
Dynamic Log Buffer (50 entries):
at 0 days 0 hours 2 minutes 0 seconds, level alert
Temperature 48.0 C degrees, warning level 45.0 C degrees, shutdown level 55.0 C
degrees
at 0 days 0 hours 1 minutes 0 seconds, level alert
Temperature 40.0 C degrees, warning level 35.0 C degrees, shutdown level 45.0 C
degrees

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brocade Communications Systems FWS624 and is the answer not in the manual?

Brocade Communications Systems FWS624 Specifications

General IconGeneral
BrandBrocade Communications Systems
ModelFWS624
CategorySwitch
LanguageEnglish

Related product manuals