2-34
Confidential
■ Error Code 75
Head capping does not work normally.
Error Code 76
Head uncapping does not work normally.
<User Check>
- Remove the jammed recording paper from the Platen part and the Maintenance unit part.
■ Error Code 7E
Head property information not input.
Unable to print 75
LCD
Unable to print 76
LCD
Step Cause Solution
1 Foreign materials inside the
Maintenance unit
Remove foreign materials.
2 Foreign materials inside the
Engine unit
Remove foreign materials.
3 Carriage motor defective Replace the Carriage motor ASSY.
4 Maintenance unit defective Replace the Maintenance unit.
5 Main PCB defective Replace the Main PCB ASSY.
Unable to print 7E
LCD
Step Cause Solution
1 Head property information not
input
Input the head property information.
(Refer to Chapter 5, Section 1.4.22)
2 Main PCB defective Replace the Main PCB ASSY.