288
Troubleshooting
9-3. Error message
What is shown below is the error message list of the GTX-4 printer. Any error message is displayed on the liquid crystal
panel.
Please try to solve any error according to the resolution strategy.
Error code
Error message Description Remedy
1000
[Cleaning Solution Low -
Add More]
The remaining cleaning
solution is running low.
With reference to "6-2-2. Confirmation and
replenishment of cleaning solution >>P.126",
replenish the cleaning solution.
1001
[Cleaning Solution Out -
Add More]
The cleaning solution has
been depleted.
With reference to "6-2-2. Confirmation and
replenishment of cleaning solution >>P.126",
replenish the cleaning solution.
1030
[Color Head Getting
Warm]
It is the warning about
temperature increase in the
color heads.
Please wait until the temperature decreases.
If the problem still persists, please contact your
dealer.
1031 [W Head Temp Rising]
It is the warning about
temperature increase in the
white heads.
Please wait until the temperature decreases.
If the problem still persists, please contact your
dealer.
1060 [Temp Low]
The ambient temperature
decreases below the scope
covered by its warranty for the
best print result.
With reference to "10-1. Apparatus >>P.315",
increase the room temperature.
1061 [Temp High]
The ambient temperature
rises above the scope
covered by its warranty for the
best print result.
With reference to "10-1. Apparatus >>P.315",
decrease the room temperature.
1064 [Humidity too Low]
The humidity decreases
below the scope covered by
its warranty for the best print
result.
With reference to "10-1. Apparatus >>P.315",
increase the room's humidity.
1065 [Humidity too High]
The humidity level is higher
than the scope covered by its
warranty for the best print
result.
With reference to "10-1. Apparatus >>P.315",
decrease the room's humidity.
1070 [Battery To Be Replaced] Battery needs to be replaced.
Make note of their error code and error message,
and please notify it to your dealer.
1080 [RTC Not Adjusted]
The built-in clock has not
been set up.
Make note of their error code and error message,
and please notify it to your dealer.
1085 [RTC Not Adjusted]
The built-in clock has not
been set up.
Make note of their error code and error message,
and please notify it to your dealer.
1090 [Cap/Wiper Cleaning]
Cap and wiper need to be
cleaned.
With reference to "7-1-2. Cleaning the nozzle
guard, wiper, exhaust cap, and suction cap
>>P.177", clean the cap and wiper.
1091 [Cap/Wiper Cleaning]
Cap and wiper need to be
cleaned.
With reference to "7-1-2. Cleaning the nozzle
guard, wiper, exhaust cap, and suction cap
>>P.177", clean the cap and wiper.