1-35
Confidential
Ghost
Fogging
CAUTION:
This problem often occurs when the drum unit or toner cartridge is nearly at the end of life.
User Check
Check the machine's environment, conditions such as high or low
humidity may cause this situation to occur.
Check that the appropriate media type or size is selected in the
printer driver.
Replace the drum unit with a new one.
Step Cause Check
Result
Remedy
1
HVPS PCB
failure
Is the problem solved
after replacing the
HVPS PCB ASSY?
Ye s
Replace the HVPS PCB
ASSY.
2
Main PCB failure Is the problem solved
after replacing the main
PCB ASSY?
Ye s
Replace the main PCB
ASSY.
User Check
Replace the toner cartridge with a new one.
Replace the drum unit with a new one.
Do not use acid paper.
Check if there is dust or paper powder in the machine.
Step Cause Check
Result
Remedy
1
Toner sensor
failure (Machine
body)
Is the toner sensor
performed normally by
following the procedure
in "Factory Inspection
Mode" (Chapter 5).
No
Replace the toner sensor
PCB unit ASSY and the
toner LED PCB ASSY.
2
HVPS PCB
failure
Is the problem solved
after replacing the
HVPS PCB ASSY?
Ye s
Replace the HVPS PCB
ASSY.
3
Main PCB failure Is the problem solved
after replacing the main
PCB ASSY?
Ye s
Replace the main PCB
ASSY.