6-24
Trouble Action to be taken
(9) White vertical streaks At the scanner
Check the following components:
- CCD unit
At the printer side
Clean the laser beam window on the laser unit.
Replace the toner cartridge.
Replace the drum unit.
(10) White horizontal stripes At the printer side
Replace the drum unit.
(11) Dropout, white spots, or
hollow print
At the printer side
Check the connection of the high-voltage power flat cable on the
main PCB and high-voltage power supply PCB.
Replace the toner cartridge.
Gently wipe off the surface of the photo-sensitive drum with a
cotton swab.
Replace the drum unit.
Replace the high-voltage power supply PCB.