Loading...
9
WSW06
(Pause key setting and 2nd dial tone detection)
Selector
No.
Function Setting and Specifications
1
|
3
Pause key setting and 2nd dial tone
detection
No. 1 2 3
0 0 0 : No pause
0 0 1 : 3.5 sec. WAIT
0 1 0 : 7 sec. WAIT
0 1 1 : 10.5 sec. WAIT
1 0 0 : 14 sec. WAIT
1 1 0 : 2nd dial tone detection
only in pulse dialing (DP)
system
1 0 1 : 2nd dial tone detection
1 1 1 : both in DP and push-
button (PB) dialing system
4
|
6
Detection of 2nd dial tone
No. 4 5 6
0 0 0 : 50 ms
0 0 1 : 210 ms
0 1 0 : 500 ms
0 1 1 : 800 ms
1 0 0 : 900 ms
1 0 1 : 1.5 sec.
1 1 0 : 2.0 sec.
1 1 1 : 2.5 sec.
7
No. of 2nd dial tone detection
times
0: Once 1: Twice
8
2nd dial tone interrupt detecting
time
0: 30 ms 1: 50 ms

Table of Contents