ulse
dialing
0: OFF 1: ON
8
Beep when the memory area for the
activity report becomes full
0: No 1: Yes
NOTE: Selectors 7 and 8 are applicable to the European version only.
Selector 8: Beep when the memory area for the activity report becomes full
If this selector is set to "1," the machine will beep when the memory area for the activity report
becomes full (as well as displaying a message on the LCD, prompting the output of the activity
report).
WSW30 (Function setting 8)
Selector
No.
Function Setting and Specifications
1
|
3
Not used.
4
Duty cycle control of pulsed current
for the heat-fixing unit
0: OFF 1: ON
5
|
8
Not used.
NOTE: Selector 4 is applicable to the European version only.
Selector 4: Duty cycle control of pulsed current for the heat-fixing unit
Setting this selector to "1" activates the duty cycle control that suppresses the rush current. The
duty cycle is 10-ms ON and 20-ms OFF.
However, the duty cycle control may emit switching noise to the AC line. Depending upon the
codes and regulations in the country, this selector should be set to "0."