45
WSW46
(Monitor of power ON/OFF state)
Selector
No.
Function Setting and Specifications
1
2
Monitoring the PC ON/OFF state
No. 1 2
0 0 : Disabled
0 1 : Monitor SELECT IN
1 0 : Monitor STROBE
1 1 : Monitor both SELECT IN and
STROBE
3
Parallel port output pins kept at
high level
0: Enabled 1: Disabled
4
|
8
Not used.
NOTE: Selector 3 is applicable only to models equipped with a parallel interface.
Selectors 1 and 2: Monitoring the PC ON/OFF state
For the related functions, refer to WSW36, selectors 2 and 3.
Selector 3: Parallel port output pins kept at high level
Setting this selector to "0" will keep all parallel output pins of the machine at high level. Use this
setting if Resource Manager (bundled with MFC models) installed to WindowsNT running on the
connected PC fails to monitor the power ON/OFF state of the machine.