4-24
n Reassembling Notes
• When setting the document tray on the scanner unit, pass the bound harnesses (ADF motor
harness, document sensor harness, document tray open sensor harness, and grounding wire)
through the front section of the opening provided in the left rear corner of the document tray,
with its bound section facing up (see the illustration given on page 4-22).
Move those bound harnesses to the rear section of the opening. Route the bound section through
the cable guide so that the cable binder comes into contact with the cable guide as illustrated on
page 4-22. Refer to Subsection 4.1.25 "Harness routing A."
• When putting the scanner unit on the scanner mount, take special care not to bend, wrinkle, or
scratch the CCD flat cable or not to break the boss of the front cover by the bottom of the
scanner unit. (See the illustration given on page 4-20.)
• Route the document sensor harness, document tray open sensor harness, ADF motor harness,
panel harness, and grounding wire on the scanner mount as shown on page 4-21. Wind the
document sensor harness and document tray open sensor harness around the cable clip on the
relay PCB, and then bend the cable clip as shown in Subsection 4.1.25, "Harness routing B."