EasyManua.ls Logo

Bryant Evolution Connex SYSTXBBECC01- User Manual

Bryant Evolution Connex SYSTXBBECC01-
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Installation Instructions
SYSTXBBECC01-- B
EvolutionR Connext Control
NOTE: Read the entire instruction manual before starting the installation.
NOTE: Please r efer to the literature provided with the connected HVAC equipment
for more det ai l s on s yst em operations wi t h specific pi eces of equi p ment.
The features and functions outlined in the Installation Instructions reflect Version 1
soft w ar e. See the Evol ution Connex product page on the HVACPartners . com websit e or
the Downl oads sect ion of the www.MyEvolut i onC onnex.Bryant. c om
websi te for the
latest software release and literature.
US Patents: Carrierr U . S. Pat No. 7,243,004, C a rr ierr U.S. Pat No. 7, 775,452,
point SETt U.S. Pat No. 7,415,102

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Bryant Evolution Connex SYSTXBBECC01- and is the answer not in the manual?

Bryant Evolution Connex SYSTXBBECC01- Specifications

General IconGeneral
CategoryController
ModelSYSTXBBECC01-
BrandBryant
Control TypeTouchscreen
Humidity ControlYes
DehumidificationYes
ConnectivityWi-Fi
AlertsYes
Energy MonitoringYes
Energy ManagementYes
GeofencingYes
CompatibilityEvolution System
DisplayColor
Remote AccessYes
Power Source24V
Voice ControlYes
ZoningYes

Summary

Safety Considerations

Introduction

Quick Start

Set Time and Date

Manually set or synchronize time and date using the menu options.

Manually Adjust Time and Date

Set hour, minute, month, day, or year using up/down buttons and save.

Setup Time Zone

Select the time zone for the location from the menu options.

Enable Time Synchronization

Enable time synchronization for Wi-Fi capable controls after setting time zone.

Set Dealer Information

Installation

Overview

Covers installation of Connex Control and Wireless Access Point; setup, commissioning overview.

Check Equipment

Inspect equipment for damage or completeness before installation.

Location

Guidelines for placing the Wall Control and Remote Room Sensors.

Wiring Considerations

General guidelines for thermostat wire selection and usage.

Mounting

General instructions for mounting the Evolution Connex Control.

Humidifier Connections

Connecting bypass and fan powered humidifiers.

Commissioning

Searching for Indoor Unit

Control searches for and identifies the indoor unit during commissioning.

Searching for Outdoor Unit

Control searches for and identifies the outdoor unit during commissioning.

Indoor Evaporator Selection

Select the indoor evaporator coil for correct refrigerant charge calculation.

Electric Heater Selection

Select the appropriate electric heater size if not self-identifying.

Hydronic Heat Application

Supports hot water coil applications with fan coil or as sole heat source.

Searching for SAM Module (If Applicable)

Checks for System Access Module for home automation.

Searching for Zones (If Applicable)

Determines if zones are present and identifies sensors associated with them.

Filter Type Selection

Select the air filter type installed with the Evolution System.

Humidifier Installation

Select whether a humidifier is installed in the system.

Ultraviolet Lights Installation

Select whether ultraviolet lights are installed in the system.

Equipment Summary

Displays a summary of all automatically found or manually selected equipment.

Airflow Verification Check

Checks system airflow and displays static pressure or target airflow CFM.

Duct Assessment (zoned systems only)

Measures ductwork size and airflow for zoned systems.

Service Menu

Equipment Summary

Shows installed indoor/outdoor unit types, filter, accessories, and zone count.

Installation

Perform start-up process to learn all equipment in the system.

Set up

Accesses configuration menus for various system components.

Check out

Perform checkout tests to ensure proper operation of installed equipment.

Service Information

View installed equipment information and diagnostic tools.

Refrigerant Charging: Greenspeed® Intelligence, 18VS™, 19VS™ Systems

Charging

Enter lineset length, vapor line diameter, and verify charge.

Pump down

Assist in isolating refrigerant into the outdoor unit using pump down procedure.

Evacuation

Open EXV for evacuation or refrigerant recovery.

EXV Position

Set the EXV position and monitor suction pressure.

Dealer Logo

Wireless Set-up

Setup and Status Information (Homeowner’s Router)

Establish Wi-Fi connectivity using the homeowner's router.

Setup and Status Information (Dealer-provided Router)

Wiring Diagrams