EasyManua.ls Logo

BT SWE140L - Page 77

BT SWE140L
230 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
Error codes
© BT Repair manual SWE100, 120, 120L, 120S, 140, 140L, 200D 7 – 19
Order no.. Date Valid from serial no. T code
258946-120 2012-08-30 6061850- 841×842×843
4.521
The main contactor is open. Pump motor voltage too low.
Check:
the wiring harness between the
transistor regulator and the pump
motor
the pump motor.
4.522
The main contactor is open. Pump motor voltage too high.
Check:
the wiring harness between the
transistor regulator and the pump
motor.
the pump motor.
4.540
Transistor regulator stops all functions. The transistor regulator output to the
lowering valve is short-circuited.
Internal short-circuit in the transistor
regulator.
Inspect the connections and wiring
harness.
Disconnect the wiring to the lowering
valve and try restarting the truck.
If the error remains, replace the
lowering valve or the transistor
regulator.
4.541
Transistor regulator stops all functions. The transistor regulator output to the
lowering valve is short-circuited to B-.
Inspect the connections and wiring
harness.
4.560
Transistor regulator stops all functions. The transistor regulator output to the
lowering valve is open.
Check:
connections and wiring harness
the lowering valve coil.
Code Event Possible cause
Action