EasyManua.ls Logo

BT SWE200D - Page 74

BT SWE200D
230 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7 – 16 Repair manual SWE100, 120, 120L, 120S, 140, 140L, 200D © BT
Troubleshooting
Error codes
T code Valid from serial no. Date Order no.
841×842×843 6061850- 2012-08-30 258946-120
3.539
Transistor regulator stops all functions. The transistor regulator detects that the
battery voltage is not in the interval 18
V - 28.8 V.
Check:
the wiring harness between the
battery and transistor regulator.
the battery.
3.540
Transistor regulator stops all functions. The transistor regulator output to the
main contactor has short-circuited.
Check:
connections and wiring harness
the main contactor.
3.541
Transistor regulator stops all functions. The transistor regulator output to the
parking brake is short-circuited.
Check:
connections and wiring harness
the parking brake.
3.542
Transistor regulator stops all functions. One of the transistor regulator's circuits
to the main contactor, parking brake or
lowering valve is short-circuited to
+24
V at start-up.
Check
connections and wiring harness
main contactor
parking brake
the lowering valve.
3.560
Transistor regulator stops all functions. The transistor regulator output to the
main contactor has short-circuited.
Check:
connections and wiring harness
the main contactor.
3.561
Transistor regulator stops all functions. The circuit between the transistor
regulator and the main contactor coil is
open.
Check:
connections and wiring harness
the main contactor.
Code Event Possible cause