Functions and parameters
Parameters
© BT Repair manual SWE100, 120, 120L, 120S, 140, 140L, 200D 6 – 17
Order no.. Date Valid from serial no. T code
258946-120 2012-08-30 6061850- 841×842×843
6.5.6 Factory parameters
Setting of the truck factory parameters is done during production at the
factory. Factory parameters can only be changed using the TruckCom
software application in a PC or PDA.
Note:
Bear in mind that a change to specific truck parameters will change
the truck’s characteristics. Do not change any parameter values
without the necessary know-how. Only authorised service
technicians with personal user identity for TruckCom has the
authority to change factory settings. This may only be done if special
needs arise.
The user ID and time of parameter change are logged in the circuit
board of the handle.
Param
eter
Designation/
unit
Min./
Max.
Incr
eme
nt
Def
aul
t
Description
1001 Truck type 0/8 1 0 0 = Unknown truck type
1 = SWE100
2 = SWE120
3 = SWE140
4 = SWE120L
5 = SWE140L
6 = SWE200D
7 = SWE080L
8 = SWE120S
1002 Non-configurable
options
0/3 1 1 3 different functions are accessible
via parameter 1002. These
functions are either active or
inactive. The functions do not
require any further adjustment and
are thus referred to as non-
configurable options.
0 = No option function
1 = Click-2-Creep
2 = Turtle function
3 = Both Click-2-Creep and Turtle
function.
1003 ConfOption Func1 0/13 1 0 Requires SEU
1004 ConfOption
Func1Arg1
0/255 1 0 Requires SEU
1005 ConfOption
Func1Arg2
0/255 1 0 Requires SEU
1006 ConfOption
Func1Arg3
0/255 1 0 Requires SEU
1007 ConfOption
Func1Arg4
0/255 1 0 Requires SEU