Troubleshooting
Troubleshooting chart
© BT Repair manual SWE100, 120, 120L, 120S, 140, 140L, 200D 7 – 27
Order no.. Date Valid from serial no. T code
258946-120 2012-08-30 6061850- 841×842×843
7.6.4 The truck travels, but some functions
do not work.
Software compatibility
Make sure that correct software for logic card [A5] and transistor
regulator [T1] as well as battery charger [A30] are downloaded in the
truck.
See section "7.1 General".
Hardware compatibility matrix
Make sure the correct software of the logic card [A5] and the transistor
regulator [T1] have been installed in the truck by referring to the matrix
below.
ACT was not replaced
transistor regulator[T1]
ACT replaced
transistor regulator[T1]
ICH was not replaced
logic card [A5]
OK Warning 2.004. Use TruckCom
to download new backup values.
Open TruckCom, and select
“Copy configuration to
secondary unit: ACT”
ICH replaced
logic card [A5]
Error code 2.101. Use TruckCom
to upload new backup values.
Select “Copy configuration to
primary unit: ICH”
Replace one node at a time and
implement the corresponding
measure. See 17.2 and 16.5.2
https://www.besttruckmanuals.com/