EasyManua.ls Logo

BT SWE200D - Built-In Test Function

BT SWE200D
230 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
Built-in test function
© BT Repair manual SWE100, 120, 120L, 120S, 140, 140L, 200D 7 – 31
Order no.. Date Valid from serial no. T code
258946-120 2012-08-30 6061850- 841×842×843
7.7 Built-in test function
The truck control system has a number of built-in test functions that can
be used to aid the troubleshooting process. To activate the test
functions:
1. Connect the CAN service key to [X41] and log in.
2. Battery status symbol is lit.
3. Press the horn button [S18] repeatedly to choose Built-in Test
function.
Note:
All truck functions operate as normal in this mode. Care should be
taken when operating the truck and reading the display at the same
time.
Mod
e
Flashing symbol Data shown in the display Normal value
1 Battery voltage (V)
2 Current across battery (A) -
3 The set speed value that is sent to the
transistor regulator
Min.: -142
Max: 142
4 Travel speed value from travel speed
sensor
Min: approx. -140
Max: approx. 140
5 Fork lowering on/off
Fork lifting on/off
To: 1 Off: 0
On: 2 Off: 0
6 Fork under mast sensor #1 On (0V): Down
Off (>5V): Up
7 N/A -
8 N/A -
9 Input/output status, transistor regulator
[T1]
-
10 Input/output status, logic card [A5] -
https://www.besttruckmanuals.com/