EasyManua.ls Logo

BT SWE200D - Page 54

BT SWE200D
230 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 – 16 Repair manual SWE100, 120, 120L, 120S, 140, 140L, 200D © BT
Functions and parameters
Parameters
T code Valid from serial no. Date Order no.
841×842×843 6061850- 2012-08-30 258946-120
206 Deceleration, % 10/
100
5 60 Determines the motor's braking power
when the speed control is placed in the
neutral position and the forks are above
1.8 m. The lower the value of this
parameter, the longer the time to
decelerate.
301 Lowering stop
ramp
3/20 1 7
Determines the closing ramp of the
proportional valve.
302 Fork lowering
speed
70/
255
5 190
Determines the maximum lowering speed of
the forks. This parameter can be adjusted
manually or can be set by using the
calibration function (parameter 108 = 1).
303 EVP start
position
30/
150
5 90
Determines the start position of the
proportional valve. This parameter can be
adjusted manually or can be set by using the
calibration function (parameter 108 = 1).
304 EVP support
arms lowering
speed
50/
220
5 130
Determines the lowering speed of the
support arms. This parameter can be
adjusted manually or can be set by using the
calibration function (parameter 108 = 1).
305 EVP slow
lowering speed
40/
220
5 105
Determines the slow lowering speed when
using "Click-2-Creep”. This parameter can be
adjusted manually or can be set by using the
calibration function (parameter 108 = 1).
306 Activate two
lifting/lowering
speeds
0/1 1 1
Activate “Click-2-Creep” lifting/lowering
0 = Off
1 = On
307 Activate
automatic
lowering of the
support arms
0/1 1 1
Activate automatic lowering of the support
arms
0 = Off
1 = On
Param
eter
Designation/
unit
Min./
Max.
Incr
eme
nt
Def
ault
Description