Functions and parameters
Parameters
© BT Repair manual SWE100, 120, 120L, 120S, 140, 140L, 200D 6 – 15
Order no.. Date Valid from serial no. T code
258946-120 2012-08-30 6061850- 841×842×843
110 Battery charger,
battery
capacity, Ah
0/300
(100/
300)
1 0
(100)
Determines the battery capacity.
0 (100) = No charging. Default setting. An
error code is displayed if this parameter
has been set to 0 (100) when a battery
charger has been installed and factory
parameter 1101 has been set to 1.
The value in brackets () indicates if the
truck has software version -006 or newer.
For more information, see the Installation
chapter.
111 Resetting
following a
collision
0/1 1 0 0 = A special PIN code is required to reset
the truck after a collision.
1 = The truck can be reset using all the
activated PIN codes.
2 = Horn sounds once every five seconds.
3 = Options 1 and 2 combined.
201 Reverse
braking
70/
100
5 100 Specifies how hard the truck should brake
when the speed control is turned fully in
the opposite direction.
Note: This value must not be set lower
than the value of parameter 5. If it is lower,
error code 2.002 is shown at start-up and
the value is not changed.
202 Creep speed -200/
200
5 0 Determines the speed the truck will have
when it reaches the value set for the first
travel speed sensor
.
-200 = Low speed for the first speed
sensor.
200 = High speed for the first speed sensor
203 Maximum
speed, %
10/
100
5 45 Determines the maximum speed of the
truck when the forks are higher than 1.8 m.
204 Acceleration, % 10/
100
5 45 Determines the maximum acceleration
capacity of the truck when the forks are
higher than 1.8 m. The lower the value of
this parameter, the longer time it takes for
the truck to accelerate to top speed.
205 Reverse
braking, %
10/
100
5 80 Determines how hard the truck will
decelerate when the forks are higher than
1.8 m and the speed control is turned in
the opposite direction to the travel
direction.
Param
eter
Designation/
unit
Min./
Max.
Incr
eme
nt
Def
ault
Description