16
Technical data
Digital input DI
supply voltage
input impedance
min. pulse duration
protections
18-36 V DC
15 kW
200 ms
galvanically isolated, and protected against polarity
reversals and voltage spikes
6.3.4. Electrical connection
Type of connection Through two M20x1,5 cable glands
Cable specifications
cable type
Cross section
Diameter of each cable:
- if only one cable is used per cable gland
- if two cables are used per cable gland
shielded
0,5 to 1,5 mm
2
- 6...12 mm
- 4 mm, with the supplied multi-way seal