TECHNICAL FEATURES
Environment features
Features Unit All devices
Power voltage
V 230 +10% / -15%
Hz 50/60 Hz
Maximal pressure bar 7
Recommended minimal pressure bar 2
Minimal water temperature °C 1
Maximal pressure temperature °C 35
Ambient air minimal temperature °C Frost free
Ambient air maximal temperature °C 40
Operational features
Resin volume liters 5 10 16 20 22 28
Salt consumption per regeneration kg 0,50 1,25 2,00 2,50 2,75 3,50
Softening capacity for 15°f hardness
drop of (around 8.5 °dH)
liters 1650 2300 4800 5300 5900 7500
Softening capacity for 20°f hardness
drop of (around 11 °dH)
liters 1250 1800 3600 4000 4400 5600
Softening capacity for 25°f hardness
drop of (around 14 °dH)
liters 1000 1400 2900 3200 3500 4500
Softening capacity for 30°f hardness
drop of (around 17 °dH)
liters 800 1200 2400 2700 2900 3700
Softening capacity for 35°f hardness
drop of (around 19.5 °dH)
liters 700 1000 2100 2300 2500 3200
Softening capacity for 40°f hardness
drop of (around 22.5 °dH)
liters 600 900 1800 2000 2200 2800
Average water consumption per re-
generation
liters 50 60 70 100 100 120
Electrical consumption in service VA 6
Electrical consumption in regeneration VA 25
(1) - The above data are given for a network water pressure of 4 bars and the factory settings.
(2) - The softening capacity in the above board is the volume 100% treated.