Table 10 Online Diagnostics RSSI Display
Value
RSSI
Notes
0
NA
The RSSI Value is not Available
1
> -60.25 dBm
The RSSI Value is greater than 60.25 dBm
20
-65.00 dBm
255
< -123.75 dBm
RSSI is less than 123.75 dBm
X
RSSI = -60 (X * 0.25), for X not equal to 0
4.2 SETUP WIZARD
Refer to Section 3.5.2 Quick Start to use the Setup Wizard to configure your Viper.
4.3 BASIC SETUP
From the navigation frame, select Basic Setup to configure General, IP, Channel Table and Serial Port settings.
General Settings (see Section 4.3.1)
IP Settings (see Section 4.3.2)
Channel Table Settings (see Section 4.3.3)
Serial Port Settings (Section 4.3.4)
4.3.1 GENERAL
Figure 21 Setup(Basic)General Settings
Station Name. Enter a string up to forty characters in length.