p. 18 - Manual FA01317-EN - 01/2020 - © CAME S.p.A. - The contents of this manual may be changed at any time and without notice. - Translation of the original instructions
Automatic closure
Activate automatic closing.
[FUNCTIONS] [Automatic close] [Deactivated]
[Activated] (Default)
Hold-to-run
With the function active, the operator opening movement (command 2-3) or closing movement (command 2-4) is interrupted
when the control device is released.
When the function is active, it excludes all other control devices.
[FUNCTIONS] [Hold-to-run] [Deactivated] (Default)
[Activated]
[Closing]
Detecting obstacles
With the function active, the gate remains idle if the safety devices detect an obstacle. The function is active when the gate is
closed, open or after a complete stop.
[FUNCTIONS] [Obstruction det.] [Deactivated] (Default)
[Activated]
Safety devices test
Check that the photocells connected to the inputs are operating correctly, after each opening and closing command.
[FUNCTIONS] [Safety devices test] [Deactivated] (Default)
[CX]
[CY]
[CZ]
[CX+CY]
[CX+CZ]
[CY+CZ]
[CX+CY+CZ]
Pre-fl ashing
The fl ashing beacon is activated before each manoeuvre.
The pre-fl ashing duration is set with the [Pre-fl ashing T.] function
[FUNCTIONS] [Pre-fl ashing] [Deactivated] (Default)
[Activated]
Thrust
Before every opening or closing manoeuvre, the leaves thrust inwards to release the electric lock.
The thrust time is set with the [Thrust T.] function
[FUNCTIONS] [Thrust] [Deactivated] (Default)