5) Adjustment Startup Procedure
Load the work disk in the computer
then turn it ON. The title screen
appears as shown at right.
Turn the Multiple Tool II or HS-I/F
ON in accordance with the directions
displayed on the screen. If the
Multiple Tool II or HS-I/F is already
ON, turn it OFF and then back ON
again.
After communication has been
established between the computer,
Multiple Tool II and HS-I/F, the
screen shown at right appears.
Connect the camera to the Multiple
Tool II, and HS-I/F as indicated, then
turn ON the main switch on the
camera. When the connection is
completed, press the Return key.
It is sometimes necessary to turn the
camera's electronic dial to establish
communication. Follow the
instructions on the screen. If more
than a minute passes before the
electronic dial turns ON, an error
will occur.
The adjustment software checks that
communication has been established
with the camera, then displays the
total number of film transports,
camera's ROM version number and
error code on the screen.
The ROM version is compatible with
MPU 3E7733 and LPU 11 or later.
The details of past occurring errors
are stored to memory as error codes.
Error codes can be cleared by
selecting Clear Error Code in the Self
Check Menu.
For details on error codes, see "Modes in Which Error Nos. Are Lit at All Times" on page
2-32.
Part 4: Electrical Adjustment
4-4
:
Pressing SW1 or SW2 results
in an error.
1NOTE