When this machine is shipped from the factory,
it is filled with a mixture of 50% antifreeze and
50% water. To prevent coolant from freezing, use
a mixture of water and antifreeze determined by
the minimum temperature in the operation area
using the table on the left.
Antifreeze Mixture (Reference)
Ambient
Temperature
Antifreeze
Mixture
-10 °C
30%
-15 °C
35%
-20 °C
40%
-25 °C
45%
-30 °C
50%
-35 °C
55%
-40 °C
60%
* The value for the ambient temperature
is 5°C lower than the actual minimum
temperature.
• Antifreeze to use: Long Life Coolant (LLC).
• Use pure water to make antifreeze mixture.
NOTE
1. Prepare a suitable container for drained
coolant.
2. Remove radiator cap and reservoir lid.
3. Open drain cock at the bottom of radiator.
4. Drain coolant. Then clean inside radiator.
5. Clsoe drain cock.
6. Fill radiator and reservoir with antifreeze
mixture.
7. Put adiator cap and reservoir lid back in
place.
Changing
• Coolant Capacity: 7.2L
•Removing radiator cap helps drain the
coolant.
NOTE