Maintenance
-62-
5
After Normal Use
1. Clean the machine; wash off dirt, mud, and other foreign matter after use.
2. If the machine is to be left outside, cover the machine with protective, water-proof
covering after the machine is cooled off.
Do not wash the engine, control panel, electrical parts, or tank caps with air
breather with running water; water may enter inside and cause rust or damage.
• Clean the machine after use; leaving dirt or foreign objects may cause damage.
Do not attempt to move the machine when it becomes inoperable due to
freezing.
1. Clean the machine; wash off dirt, mud, and other foreign matter after use.
2. Park the machine on a paved or firm, dry surface.
3. If the machine is to be left outside, cover the machine with protective, water-proof
covering after it is cooled off.
After Use Care
After Cold Weather Use
1. Open engine hood.
2. Open the lid of fuse housing.
3. Locate the blown fuse and replace it with a
new one of the correct rating.
4. Put the lid back in place.
5. Close engine hood.
3670M-0506-050E
Slow Blow Fuses
Slow Blow Fuses
• Main Glow: 50A
Alternator: 30A
NOTE