HST (Hydrostatic Transmission) Fluid
• Inspect and maintain fluid level regularly. If fluid level is low, air may be trapped
into the hydraulic system, causing loss of perwormance or premature wear..
• Dispose of the drained fluid properly, according to the national and local regula-
tions.
• Burn hazard; pay special attention when handling the hydraulic fluid. Hot fluid
may cause burns.
1. Park machine on the level ground.
2. Open engine hood.
Inspecting/Filling
10. Attach grease pump to track adjuster valve
and pump grease into track adjuster cylinder
until the gap A is between 224 and 225mm.
11. Remove grease pump and install valve
cover.
• HST fluid is used for driving as well as for hydraulic apparatus .
NOTE