EasyManua.ls Logo

CanyCom S25A - Page 69

Default Icon
81 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance
-60-
5
2. Visually inspect that battery fluid level is
between the "Upper Level" and "Lower
Level" lines. If the fluid level is below the
"Lower Level," fill.
3. If battery fluid level is below "Lower Level
line, open battery filler plugs and add distilled
water up to "Upper Level" line.
4. Reinstall filler plugs.
5. Close engine hood.
1. Park machine on a level ground. Open
engine hood.
Inspecting/Filling
3670M-0506-010E
Battery
3670M-0506-020E
Upper Level
Lower Level
Filler Caps
1. Park machine on a level ground. Open
engine hood.
2. Remove battery from machine.
3. Remove all filler plugs.
4. Follow the instructions in
the battery
charger user's manual
to charge the
battery.
4. When battery is fully charged, put filler plugs
back in place.
5. Reinstall battery. Close engine hood.
• Rapid charging is only an emergency measure. This method uses a large amount of
current to compensate the lost charge in a short time. However, the battery needs
to be fully charged in the ordinary method for a longer service life.
NOTE
Charging
UPPER LEVEL
LOWER LEVEL
-
+
+ -
3570M-0509-030E