8200-M035-O1 Rev C ļ‚Ÿ 200 Installation & Technical
52
TROUBLESHOOTING, CONT.
Error Codes, Cont.
Err1 (Error 1)
A program checksum mismatch has been detected.
CORRECTIVE ACTION: Consult your scale service provider.
Err3 (Error 3)
Internal RAM failure.
CORRECTIVE ACTION: Consult your scale service provider.
HuH? (HuH?)
UNITS key pressed in an attempt to perform a unit conversion that is not allowed.
CORRECTIVE ACTION: Determine the reason for the error display and take the
appropriate corrective action.
notArE (no tarE)
NET key pressed with no stored tare weight value.
CORRECTIVE ACTION: Determine the reason for the error display and take the
appropriate corrective action.
oCAP (over Capacity)
The load on the scale exceeds the scale capacity plus nine (9) divisions.
CORRECTIVE ACTION: Remove the over capacity load from the scale platform. May
indicate an incorrect calibration.
-oF- (overflow)
The indicator is attempting to display a positive number greater than six (6) digits in length
or a negative number of more than five (5) digits.
CORRECTIVE ACTION: Return to Gross Weight mode and review Tare value. May
indicate an incorrect calibration.
toobiG (too big)
UNITS key pressed in an attempt to perform a unit conversion where the interval would
have been greater than 50.
CORRECTIVE ACTION: Determine the reason for the error display and take the
appropriate corrective action.
UnStb (Unstable)
Motion is present when trying to perform a print function.
CORRECTIVE ACTION: Wait for a stable weight display (STABLE annunciator on) before
performing any of this operation.