lb-05046-03-EN Pag.59 22/01/2014
13) N° 60 Corrupted data alarm.
Corrupted data alarm 60
This alarm is visualised on display by code 60
First case: This alarm is visualised during machine functioning
Cause: incorrect operating data in machine memory.
Result: machine shutdown.
Solution: carry out the following controls.
1) Verify programming data relevant to the operation that is being carried out. They might be varied and therefore the
machine does not recognise the new data.
2) Carry out “PARAMETERS PRESET” procedure (see chapter system programming configuration data preset).
Second case: software programming values or data incorrect, data inserted by means of P.C. programming incorrect.
Result: machine shutdown.
Solution:
1) Carry out “PRESET CONFIGURATION DATA” procedure
2) Insert new software by means of P.C.
14) N° 63 Clock error.
Clock error 63
This alarm is visualised on display by code 63
Solution: check the following:
a) run down battery
b) faulty master board
15) N° 65 Motor block alarm.
Motor block 65
This alarm is visualised on display by code 65
Causes: a mechanical block occurred to the Mixer.
Result: the machine is switched OFF.
Check the following:
1) Mixer motor defective
2) Master board defective
16) N° 66 Trasponder PCB alarm.
Trasponder pcb 66
This alarm is visualised on display by code 66
Solution: check the following :
1) Trasponder cable
2) Trasponder p c board defective
3) Faulty master board