Carrier 58HDX - Additional Propane Connection Requirements; Propane Conversion Hazard

Carrier 58HDX
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7.
Install
a
manual
shut-off
valve external
to
furnace
casing
and tighten
all
joints
securely.
8.
If
local
codes
allow
the
use
of
flexible
gas
appliance
con-
nectors,
always
use
a
new
listed
connector.
Do
not
use
a
connector
which
has
previously
serviced
an-
other
gas
appliance.
9.
Flexible
corrugated
metal
gas
connector
may
NOT
be
used
inside
the
furnace
or
be
secured
or
supported
by
the
furnace
or
ductwork.
10.
Properly
size
gas
pipe
to
handle
combined
appliance
load
or
run
gas
pipe
directly
from
gas
meter
or
Propane
gas
reg-
ulator.
11.
Install
correct
pipe
size
for
run
length
and
furnace
rating.
12.
Measure
pipe
length
from
gas
meter
or
Propane
second
stage
regulator
to
determine
gas
pipe
size.
Additional
Propane
Connection
Requirements
1.
Have
a
licensed
Propane
gas
dealer
make
all
connections
at
storage
tank
and
check
all
connections
from
tank
to
fur-
nace.
2. If
copper
tubing
is
used,
it
MUST
comply
with
limitation
set
in
National
Fuel
Gas
Code
or
CGA
codes.
3.
Two-stage
regulation
of
Propane
gas
is
recommended.
Propane
Conversion
FIRE,
EXPLOSION
HAZARD
Failure
to
follow
this
warning
could
result
in
personal
injury
or
death.
A
Propane
conversion
accessory
kit
is
required
when
operating
the
furnace
with
Propane
gas.
An
accessory
kit
shall
be
used
to
convert
to
propane
gas
use,
see
the
furnace
rating
plate
for
the
Propane
conversion
accessory
kit
part
number.
Supply
Pressure
FIRE
HAZARD
Failure
to
follow
this
warning
could
result
in
personal
injury
or
death.
Do
NOT
set
input
rating
above
that
shown
on rating
plate.
1.
A
lg"
NPT
plugged
tapping,
accessible
for
a
test
gauge
connection,
must
be
installed
immediately
upstream
of
the
gas
supply
connection
to
the
furnace.
.
Gas
input
to
burners
MUST
NOT
exceed
the
rated
input
shown
on
rating
plate.
.
Do
NOT
allow
minimum
gas
supply
pressure
to
vary
downward.
Doing
so
will
decrease
input
to
furnace.
Refer
to
Table
6
and
7
for
normal
gas
supply
and
manifold
pressures.
Manifold
Gas
Pressure
Adjustment
SEE
CHECKS
AND
ADJUSTMENTS,
Manifold
Gas
Pressure
Adjustment
in
this
manual.