Carrier 58HDX - Furnace Installation Considerations; Condensate Trap and Drain Lines; Vent and Combustion Air Connections; Horizontal Furnace Installation

Carrier 58HDX
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Furnace
Installation
Considerations
The
installation
of
the
furnace
for
a
given
application
will
dictate
the
position
of
the
furnace,
the
airflow,
ductwork
connections,
vent
and
combustion
air
piping.
Consideration
must
be
given
to
the
following:
Condensate
Trap
and
Drain
Lines
The
supplied
condensate
trap
must
be
attached
to
the
furnace
side
panel
on
either
the
left
or
right
side.
For
horizontal
installations,
the
drain
trap
is
vertically
attached
to
the
side
panel
below
the
furnace.
A
minimum
clearance
of
6"
(152
mm)
below
the
furnace
is
required
for
the
condensate
trap.
Downward
slope
of
the
condensate
drain
line
from
the
condensate
trap
to
the
drain
location
must
be
provided.
Adequate
freeze
protection
of
the
drain
trap
and
the
drain
line
must
be
provided.
See
“Condensate
Drain
Trap”
section
for
further
details.
Leveling
Proper
leveling
of
the
furnace
must
be
provided
to
insure
proper
drainage
of
the
condensate
from
the
furnace.
The
furnace
must
be
level
to
within
1/4"
(6
mm)
from
front
to
back
and
from
side
to
side
for
upflow
and
downflow
installations
or
top
to
bottom
for
horizontal
installations.
Vent
and
Combustion
Air
Connections
For
venting
information
literature,
contact
www.carrier.com
with
the
complete
model
and
serial
number
of
the
furnace.
On
the
Dual
Certified
furnace,
the
vent
and
combustion
air
pipes
attach
to
the
furnace
through
the
top
panel
for
the
upflow
and
horizontal
installations.
For
the
downflow
installation,
the
vent
and
combustion
air
pipes
attach
to
the
furnace
through
the
alternate
locations
on
the
furnace
side
panels.
NOTE:
On
the
Direct
Vent
furnace,
the
vent
pipe
attaches
to
the
furnace
through
the
side
panels.
The
combustion
air
pipe
attaches
to
the
top
panel
or
to
the
alternate
location
on
the
side
panel.
On
the
Single
Pipe
furnace,
the
vent pipe
attaches
to
the
furnace
through
the
furnace
side
panels.
NOTE:
Repositioning
of
the
combustion
blower
is
required
for
the
vent
pipe
connection
to
the
furnace
through
the
“right
side”
panel.
See
“Vent
and
Combustion
Air
Piping”
section
for
further
details.
Horizontal
Furnace
Installation
Vent
=
a
ae
NOTE:
6”
bottom
clearance
required
for
condensate
trap.
A07703
Fig.
3
-
Typical
Horizontal
Installation
This
furnace
can
be
installed
horizontally
in
an
attic,
basement,
crawl
space,
alcove,
or
suspended
from
a
ceiling
in
a
basement
or
utility
room
(See
Fig.
3).
Do
not
install
furnace
on
its
back
as
safety
control
operation
will
be
adversely
affected.