Carrier 58HDX - Carbon Monoxide Poisoning

Carrier 58HDX
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table
3
Pipe
Diameter
Table
PIPE
DIAMETER
TABLE
58HDX
MODEL
60,000
BTUH
Furnaces
10’
(3.0
M)
&
(8)
90°
elbows
with
1.5”
(13
mm)
PVC
pipe
(
)
40'
(12.1
M)
&
(5)
90°
elbows
with
2”
(51
mm)
PVC
pipe
or
70'
(21.3
M)
&
(5)
90°
elbows
with
3”
(76
mm)
PVC
pipe
80,000
BTUH
Furnace
40'
(12.1
M)
&
(5)
90°
elbows
with
2”
(51
mm)
PVC
pipe
or
40'
(12.1
M)
&
(5)
90°
elbows
with
3”
(76
mm)
PVC
pipe
100,000
BTUH
Furnace
10’
(3.0
M)
&
(2)
90°
elbows
with
2”
(51
mm)
PVC
pipe
or
40’
(12.1
M)
&
(5)
90°
elbows
with
3”
(76
mm)
PVC
pipe
Elbows
are
DWV
Long
Radius
Type
for
2”
(51
mm)
and
3”
(76
mm)
vents.
If
more
than
five
elbows
are
required,
reduce
the
length
of
both
the
inlet
and
exhaust
pipes
5’
(1.5
M)
for
each
additional
elbow
used.
If
less
than
five
elbows
are
required,
the
length
can
be
INCREASED
by
5’
(1.5
M)
for
each
additional
elbow
NOT
used.
NOTE:
It
is
allowable
to
use
larger
diameter
pipe
and
fitting
than
shown
in
the
tables
but
not
smaller
diameters
than
shown.
For
“Concentric Termination
Kit”
Venting
see
Table
4
in
this
manual.
Vent
Termination
Clearances
4.
WARNING
CARBON
MONOXIDE
POISONING
HAZARD
Failure
to
follow
this
warning
could
result
in
personal
injury
or
death.
Inlet
and
outlet
pipes
may
NOT
be
vented
directly
above
each
other.
1.
Determine
termination
locations
based
on
clearances
spe-
cified
in
following
steps
and
as
shown
in
Fig.
7,
8,
Fig.
21
through
Fig.
23.
For
“Concentric
Termination
Kit’
clearances,
see
Fig.
30
through
Fig. 35
in
this
manual.
2.
For
Direct
Vent
Installation
refer
to
Fig.
7
for
vent
termin-
ation
clearances.
3.
For
Single
Pipe
Installation
refer
to
Fig.
8
for
vent
termin-
ation
clearances.
14

Other manuals for Carrier 58HDX

Related product manuals