VENT
TERMINAL
OX)
ale
SUPPLY
INLET
AREA
WHERE
TERMINAL
IS
NOT
PERMITED
thar
Clearance
Description
Canadian
inetallation
(1)
U.S.
Installation
(2)
A
Clearance
above
grade,
veranda,
porch,
duck, baloany,
or
12
inches(30
om)
#
42
inches
(30
ern}
anticipated
enow
level
8
|
Clearance
to a
window
or
door that
may
be
opened
12
inches
(30
om)
for
appliances
>
10,000
Btuh
(9
KW)
9
Inches
(23
om)
for
appliances
2.
40,000
Btuh
(SKW)
and
=
arid
«2
100,000
Btuh
(30
kW),
36
inches:
See
Buh
ree
inches
(30cm)
for
appliances
>
(91
cm}
for
appliances
>
100,000
Btuh
(30
KW)
G
Clearance
to
a
permanently
closed
window
« *
Do
Vertical
clearance
to
2
ventilated
aoffit
located
above
the
*
.
terminal
within
a
horizonial
distance
of
2
feet(6
tem)
from
the
canteriine
of
the
terminal
E
Clearance
to
an
urwentilated
soffit
. .
F
Clearance
to
an
outside
corner
* *
g
Clearance
to
an
inside
corner
* *
H
Cleararice
to
each
side
of
the
centerline
extended
above
3
feat
(91
cm)
within
15
feat (4.6
m)
above
tha
mater/reguiator
|
3
feet
(81
om)
witht
16
faet(4.5
m) above
the
electrical
meter
or
gas service
regulator
assembly
assembly
metenregulator
ascambly
I
G
toservice
vent
outiet
3
feet (97
cm)
.
J
Clearance
to
non-mechanical
air
supply
inlet
to
building
OF
|
12
inches
(30
cm)
for
applieances
>10,000
Btuh(3
kW)
9
inches
(23
om)
for
appliances
>
10,000
Btuh
(kW)
and
the
combuetion
air
inlet
to
any
other
appliance
and
<_
100,000
Btuh(30kW),
36
inches
(91cm)
for
=
50,000
Btuh
(15k),
12
inches
(30cm]
for
appliances
appliances
>
100,000
Btuh(30kW)
>
50,000
Bluh
(15k)
x
Clearance
to
a
mechanical
air
supply
intet
6
feat
(1.63
m)}
3
faet(91
cm)
above
if
within
10
feat
(@mjhorizontally
L
Clearance
under
a
veranda,
porch,
deck,
or
baloony
12
inches(30
em)
+
*
M
Clearance
to
each
side
of
the
centerline
extended
above
or
12
Inches{(30
om)
12
Inches
(30cm)
below
vent
terminal
of
the
furnace
to
a
dryer
or
water
heater
vent,
or
other
appliance’s
direct
vent
intake
ar
exhaust.
N
Clearance
to
the
vert
terminal
of
a
dryer
vert,
water
heater
|
9
feet
(9% orm)
3
feet
(61
orn}
vent,
or
olher
appliances
direct
vent
intake
or
exhaust.
Oo
Clearance
from
4
plumbing
vent
stack
3
feat (9% err)
3
feat
(64
on
Clearance
above
paved
sidewalk
or
paved
ryt
*
e
ar
located
on
public
ity
7
test
(2.1
amy
(1.2
Inascordance
with
the
current
CSA
8149.1,
Natural
Gas
and
Propane
Installation
Code.
{2.}
In
accordance
with
the
current
ANSI
2223.
1/NFPA
54,
National
Fil Gas
Code
#
18”
(46-07)
above
rool
surface
+
Permitted
only
if
veranda,
porch,
dock,
or
balcony
ie
Tully
open
on
a
minimurn
of
two
sides
beneath
the
floor
*
Forclearances
not
specifiedin
ANS!
2223.
1/NFPA
54
or
CSA.
B149.41,
ob
in
d
with
local
di
dithe
nog
fthe
gas
supplier
and the
tanulacturer’s
installation
instructions
Avent
shall
not
te
above
a
si
or
paved
that
is
|
d
two
single
farnily
dwellings
and
serves
both
dwellings.
Notes:
La
2.
The
vent
for
this
appliance
shall
notterminate
a.
Over
public
walkways;
or
b,
Near
soffit
vents
or
crawl
space
vents
or
other
areas
whers
condensate
or
vapor
sould
create
a
nusaines
or
hazard
or
property
darnaga;
or
Gc,
Where
condensate
vapor
could
cause
damage
or
could
be
detrimental
to
the
operation
of
regulators,
relief
valves,
or
other
equipment.
When
locating
vent
terminations,
consideration
must
be
given
to
provaling
winds,
iocalion,
and
other
conditions
which
may
cause
recirculation
of
the
combustion
products
of
adjacent
venta.
Recirculation
can
cause
poor
intet
of
the
heat
exchangers.
3.
Awold
venting
under
a
deck
or
large
overhang.
Recirculation
could
occur
voor
end
cause
performance
or
aystem
problems.
Fig.
7
-
Direct
Vent
Termination
Clearance
A06675